A comprehensive solution for soft starting and stopping of three-phase asynchronous motors that increases uptime and reduces maintenance requirements.
By integrating soft starters with AC motors, you can save energy, space and costs and increase the lifetime of your system by reducing wear on motors, power cables and the electrical distribution system. And there is no need to consider filters and screened cables, as soft starters generate zero harmonics.
Supply voltages and power range
*Inside delta connection
Easy connectivity for the soft starter to EtherNet/IP-based networks, such as Rockwell PLC systems
Programming is quick and easy thanks to three menu systems (Quick Menu, Application Setup and Main Menu), a four-line graphical display and a logic keypad
The best starting and stopping profile for the application is chosen using Adaptive Acceleration Control
Motors can be used to their full potential without risk of damage from overloading due to second-order thermal model
Installation costs are lower and there is less stress on the motor thanks to DC injection braking distributed evenly over three phases
Space can be saved, cabling costs reduced and retrofitting made easier as a result of adjustable bus bars which allow for both top and bottom entry
Centrifugal pumps and fans, conveyors, crushers, grinders, mixers, compressors, centrifuges, mills and saws.
Variable speed control with AC drives enables you to reduce enegy coonsumption by running compressor applications at a lower speed.
Improve your COP and save on energy consumption by applying Danfoss AC drives to optimize the capacity control of refrigeration compressors, condensers and evaporators.
Variable speed control of a chiller allows you to provide constant pressure regulation while matching the capacity to the actual need based on measurements in the system. Speed control is beneficial when a compressor runs for long periods at partial load. Reduce operational costs by running applications at a lower speed which reduces energy consumption. And reduce installation costs by optimizing the system and the compressor itself.
Enhance your system performance, extend your equipment life, and protect against leakages, by optimizing pump operations using Danfoss AC drives.
VLT® HVAC Drives control fan speed to keep the tunnel constantly well ventilated and ensure clean air in an escape tunnel in the event of fire.
VLT® AutomationDrive FC 302 and VLT® Soft Starter MCD 500 provide quick and accurate control of high- and low-pressure seawater pumps on the remotely operated trencher laying HVAC subsea cables.
For further information or to get a quote for this soft starter please contact us