A significant part of a data center’s power consumption goes into cooling the IT equipment; in some data centers, more than 50%. With Danfoss, you get unmatched expertise, know-how, and an end-to-end portfolio of advanced technologies for cooling any data center. We can help ensure your data center cooling system meets your sustainability targets.
Get in touch
Cooling is key to protecting data center equipment. Choosing the optimal cooling solution will depend on the site size, location, and data center design.
Danfoss data center cooling solutions facilitate ideal thermal conditions around server installations. We work with OEMs, contractors, facility engineers, and operators across the globe. Together, we optimize PUE, WUE, and ERE and the capacity of data center equipment, prevent expensive downtime and keep your energy consumption and carbon footprint at a minimum.
Our unmatched portfolio covers technologies for data center cooling sources such as chillers and CRAC units to hydronic piping distribution networks, cooling terminals, air-handling units, roof-top units, fans, pumps, and much more.
All-in-one supplier of reliable, high-quality air-and liquid-cooling technologies
Highly experienced data center cooling experts
Energy efficient solutions, optimized for environmentally friendly, low GWP refrigerants
Reduced applied costs, short payback times and easy service
With Danfoss, you get advanced cooling technologies for both air and liquid cooling systems. As a world-leading supplier of HVAC technology, we offer technologies for everything from air handlers and CRAC units to temperature sensors and humidity controls.
Find an expert
The constant innovation in chiller design is driven by new demands for energy efficiency, local regulations and standards such as LEED, combined with requirements for new, low GWP refrigerants.
Today, data center cooling systems are also required to provide owners and operators with exceptional benefits. Danfoss has the solutions to meet and exceed these standards and demands:
CRAC units need to operate reliably and provide cooling in both compressor and free cooling modes, achieving high reliability, and optimal humidity and temperatures as well as part-load efficiency.
Danfoss solutions help meet energy and performance standards and low PUE targets:
Delivering outstanding efficiency and available in a wide range of configurations to meet all installation requirements.
Play video
Establishing the most accurate air supply temperature from a data center’s Air Handling Unit is critical. This requires the most accurate control of airflow through the Air Hand Unit, and water flows into the heat exchangers for heating or cooling the air flow into the data center. In most cases a variable chilled water flow system is used for this.
Danfoss solutions helps increase the energy efficiency of the data centers’ cooling source with:
Free cooling is an approach to lowering the air temperature in a building or data center by using naturally cool air or water instead of mechanical refrigeration. It delivers optimal performance by minimizing compressor operation when outdoor air temperatures are low enough to assist in cooling the chilled water loop. Power is only used to run the pumps and fans that keep the water moving, which reduces the facility’s electrical expenses and carbon footprint.
Danfoss heat exchanger solutions can be fully customized to meet your data center's exact requirements:
Complemented by high pressure pumps for reverse osmosis and evaporative systems
With the addition of a free cooling cycle, we offer a customizable, innovative solution to deliver highly reliable cooling and reduce energy cost in a sustainable way
Danfoss AC drives applied to air recirculation fans in the data center control the air flow between the racks. Removing excessive heat around the IT installations, they ensure optimal thermal conditions to protect electronic components and enable optimal performance of the servers.
By optimizing pumping operations with Variable frequency drives (VFD) it’s possible to enhance system performance significantly in refrigeration and air conditioning applications.
Installing Danfoss AC drives ensures and optimized production and protection of the drive, motor and other systemt equipment. They also ensure improved liquid supply in case of leakage or broken pipes and offers several control features and smart protection capability.
EC+: More freedom to ventilation system designers
To get high performance and system efficiency in an HVAC system, the individual components need to be broadly compatible with each other. For instance, the overall system efficiency would suffer with a high-efficiency motor that is only compatible with lower efficiency fans.
The EC+ concept from Danfoss allows system designers to combine the most efficient fan and permanent magnet motor with a VLT® HVAC Drive. This brings several advantages:
This tough and savvy FC102 drive enhances pump, fan, and chiller applications’ performance in buildings and runs outdoor in most climates.
Data centers demand the highest levels of security, reliability, and uptime. Discover how our application expertise and product portfolio of air and liquid cooling technology has been leveraged to cool data centers around the world.
For a large British manufacturer, we helped install a scalable data center cooling solution. The installation consists of 6 phases each 500m² complete with 12 high efficient cooling units, each with multiple inverter fans and compressors in order to minimize energy use and provide N+1 resilience. The units are designed to maintain the data center at 21°C ± 3°C and humidity between 20 and 80% RH.
A world-leading technology company houses multiple data centers at its 40-building campus in San Diego. To power the campus, the company uses an expansive, on-site energy infrastructure. Our expert team helped build three 1,400 Ton chillers powered by 21 Danfoss Turbocor® compressors to improve efficiency and lower costs.
Equinix’ is the world’s biggest colocation provider and connects some of the world’s leading businesses. Danfoss delivers reliable control of data center pumps and ventilators to extract as much heat as possible from server rooms to ensure a long service life for the sensitive digital equipment. Approximately 135 VLT® HVAC Drive FC 102 are in operation at the Equinix data center in Amsterdam.
The Hershey Company and Australian Broadcasting Corporation (ABC) Studios installed cooling systems with Danfoss Turbocor® compressors to ensure a continuously high performance. These variable-speed centrifugal semi-hermetic compressors use oil-free magnetic bearings to minimize oil-related performance problems and mechanical wear.
Leverage our unmatched data center portfolio
Data center owners and managers are under increasing pressure to reduce power consumption, all the while uptime and scalability are ever more critical factors. With Danfoss’ sustainable data center solutions, you can have it all.
Increase efficiency and reduce the carbon footprint with sustainable power distribution technology
Utilize excess heat and reduce your carbon footprint with innovative solutions
Minimize data center Usage Effectiveness indicis with leading solutions and consulting services
Please read our data privacy policy.
Improve your data centers’ energy efficiency, climate footprint, and uptime. With Danfoss you get unmatched expertise, experience, and end-to-end product portfolio.
Go to data centers main page